औषधि विकास और अनुसंधान के अंतर्राष्ट्रीय जर्नल

  • आईएसएसएन: 0975-9344
  • जर्नल एच-इंडेक्स: 44
  • जर्नल उद्धरण स्कोर: 59.93
  • जर्नल प्रभाव कारक: 48.80
में अनुक्रमित
  • जेनेमिक्स जर्नलसीक
  • चीन राष्ट्रीय ज्ञान अवसंरचना (सीएनकेआई)
  • उद्धरण कारक
  • Scimago
  • रिसर्च जर्नल इंडेक्सिंग की निर्देशिका (डीआरजेआई)
  • ओसीएलसी- वर्ल्डकैट
  • पबलोन्स
  • मियार
  • विश्वविद्यालय अनुदान आयोग
  • यूरो पब
  • गूगल ज्ञानी
  • शेरपा रोमियो
  • गुप्त खोज इंजन लैब्स
  • अनुसंधान गेट
इस पृष्ठ को साझा करें

अमूर्त

Process Variable Studies for the Preparation of Optimized Drug Delivery System Using Central Composite Design

Vijay Sharma1*, Ashish Singh Chauhan2, Arvind Raghav3

This research work aimed to study process variable studies for the tasteless drug resin complex of Propranolol hydrochloride and Kyron-T 314. The effect of different parameters such as swelling time, stirring time, pH, Temperature, drug resin ratio, as well as resin activation, was optimized by taste and percentage of drug loading. The formulation DRC (Drug Resin Complex) was characterized by Infrared Spectroscopy. Differential Scanning Colorimetry, and X-ray Diffraction Pattern. Tablets were formulated by the Direct Compression method with Hydroxypropyl methylcellulose (HPMC) as a binder. Sodium Starch Glycolate (SSG) and Kyron-T 314 as a super disintegration, In these batches, optimum hardness was achieved but disintegration time was found to be 30 Seconds, so further trials were planned by using different super disintegrants such as Sodium starch glycolate and Kyron-T 314 by direct compression method. Tablets formulated with 10% Kyron-T 314 showed comparatively low disintegration time (30 Sec), wetting time (26 Sec), and Friability (0.7%) than the other batches. In the present study, we optimized the conditions require for maximum drug loading of Propranolol hydrochloride and Kyron-T 314. Among different super disintegrants, Kyron-T 314 was found suitable with the Drug resin complex to get the low disintegration time, wetting time, and friability of tablets. Hence, optimized DRC batches were formulated by proper balancing of the concentration of independent variables to attain desired dependent response using 32 CCD. Thus, 32 CCD is an efficient tool in optimization experiments.

Keywords

Ion exchange resin; Central composite design; Drug resin complex; Propranolol hydrochloride; Kyron T-314

अस्वीकृति: इस सारांश का अनुवाद कृत्रिम बुद्धिमत्ता उपकरणों का उपयोग करके किया गया है और इसे अभी तक समीक्षा या सत्यापित नहीं किया गया है।