स्वास्थ्य विज्ञान जर्नल

  • आईएसएसएन: 1108-7366
  • जर्नल एच-इंडेक्स: 51
  • जर्नल उद्धरण स्कोर: 10.69
  • जर्नल प्रभाव कारक: 9.13
में अनुक्रमित
  • जेनेमिक्स जर्नलसीक
  • चीन राष्ट्रीय ज्ञान अवसंरचना (सीएनकेआई)
  • उद्धरण कारक
  • सिनाहल पूर्ण
  • Scimago
  • इलेक्ट्रॉनिक जर्नल्स लाइब्रेरी
  • रिसर्च जर्नल इंडेक्सिंग की निर्देशिका (डीआरजेआई)
  • ईएमकेयर
  • ओसीएलसी- वर्ल्डकैट
  • विश्वविद्यालय अनुदान आयोग
  • चिकित्सा शिक्षा और अनुसंधान के लिए जिनेवा फाउंडेशन
  • यूरो पब
  • गूगल ज्ञानी
  • शेरपा रोमियो
  • गुप्त खोज इंजन लैब्स
इस पृष्ठ को साझा करें

अमूर्त

The Effect of Potentialization after Electro-Stimulation Activation on Vertical Heel Performance

Bruno Caio Silva Souza, João Marcos Rodrigues de Lucena, Dhianey de Almeida Neves, Leonardo Costa Pereira, Edilberto dos Santos Barros, Laís Tonello, Elaine Vieira, Raphael Martins Cunha, Fábio Santana and Iransé Oliveira Silva

Introduction: Post Activation Potentiation (PAP) is the effect caused by a conditioning exercise with maximum or submaximal loads that promotes increased explosive strength in the subsequent activity. This phenomenon is due to the phosphorylation of light chain regulatory myosin manifesting in fast-twitch type II fibers. Electro-stimulation is a method that uses electric currents to promote involuntary muscle contraction, and its higher incidence in type II fibers because they have thicker and more superficial nerve endings.

Objective: To compare the effects of an electro-stimulation protocol with a plyometric protocol to induce PAP on vertical jump performance.

Methods: Plyometric Protocol (PP) - 2 sets of 10 ankle hops, 3 sets of 5 hundle hops, and 5 cold jumps. Electro-stimulation Protocol (EP) - Protocol 32 Neurodyn device 4 channels, Russian current, 90% of pain threshold with 3 "rise, 12" on, 3 "decay and 18" off with 70Hz frequency burst during 5 'and control condition (CC). 5 'after each protocol the Jump Power Test (JPT) was performed and 3' after the jump resistance test (RS).

Results: Only the PP produced a significant effect when compared to the other protocols (p ≤ 0.05) PP+EP (290,49 ± 14,28 e 280,36 ± 10,26) (p=0.016) and PP+CC (290,49 ± 14,28 e 280,18 ± 12,07) (p=0.006). Regarding the% fatigue, the PP protocol had indices higher than the EP protocol (p=0.054) and CC (p=0.050).

Conclusion: It was concluded that the electro-stimulation did not produce PAP effect nor in greater magnitude than the Plyometric protocol, but had the highest jump resistance compared to the control condition and plyometrics.

अस्वीकृति: इस सारांश का अनुवाद कृत्रिम बुद्धिमत्ता उपकरणों का उपयोग करके किया गया है और इसे अभी तक समीक्षा या सत्यापित नहीं किया गया है।